The NoLimit Pivot PV light inserts are ideal for demanding applications in the area of general and accent lighting. The in-house developed precision optics in the built-in LEDLUX lamps ensure precise light guidance and uniform illumination with the greatest possible glare control at the same time.
The lights are operated using 48V constant voltage power supply units available as accessories. The luminaires are always supplied with input and output cables - a terminating plug is not required due to the circuit topology used. NoLimit Pivot PV can be ordered in a grid dimension of approx. 324 mm with a minimum length of 336 mm up to a maximum length of 1975 mm.
In the case of asymmetrical beam angles, when selecting the extension cables, it must be taken into account that the position of the input cable changes depending on the alignment within the profile.
lifespan | L80B10 60,000h @ 25 ° C |
Ambient temperature | -20 ... + 35 ° C |
Storage & transport temperature | -25 ... + 70 ° C |
nominal voltage | DC 48 V |
Weight | approx. 0.6 kg / m |
Housing material | Aluminum & Polycarbonate |
Glow wire resistance | 650 ° C |
Protection class | III |
Protection mode | IP20 |
Impact resistance | IK06 |
Connection type | Connectors |
Color fidelity | SDCM 3 |
Colour rendering index | typ. 92 |
Product Code | performance class | emission angle | Light color | Luminous flux | length | width | height | Control | performance recording |
---|---|---|---|---|---|---|---|---|---|
NL PV 1000 922 NAR CV L2 | Level 2 |
15 ° x 65 °
|
2200 K
|
860 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 927 NAR CV L2 | Level 2 |
15 ° x 65 °
|
2700 K
|
1100 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 930 NAR CV L2 | Level 2 |
15 ° x 65 °
|
3000 K
|
1150 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 940 NAR CV L2 | Level 2 |
15 ° x 65 °
|
4000 K
|
1250 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 922 NAR CV L3 | Level 3 |
15 ° x 65 °
|
2200 K
|
1050 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 927 NAR CV L3 | Level 3 |
15 ° x 65 °
|
2700 K
|
1330 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 930 NAR CV L3 | Level 3 |
15 ° x 65 °
|
3000 K
|
1400 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 940 NAR CV L3 | Level 3 |
15 ° x 65 °
|
4000 K
|
1520 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 922 A1 CV L2 | Level 2 |
Asymmetric 01
|
2200 K
|
690 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 927 A1 CV L2 | Level 2 |
Asymmetric 01
|
2700 K
|
1100 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 930 A1 CV L2 | Level 2 |
Asymmetric 01
|
3000 K
|
1150 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 940 A1 CV L2 | Level 2 |
Asymmetric 01
|
4000 K
|
1250 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 922 A1 CV L3 | Level 3 |
Asymmetric 01
|
2200 K
|
840 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 927 A1 CV L3 | Level 3 |
Asymmetric 01
|
2700 K
|
1330 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 930 A1 CV L3 | Level 3 |
Asymmetric 01
|
3000 K
|
1400 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 940 A1 CV L3 | Level 3 |
Asymmetric 01
|
4000 K
|
1520 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 922 A2 CV L2 | Level 2 |
Asymmetric 02
|
2200 K
|
840 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 927 A2 CV L2 |
Asymmetric 02
|
2700 K
|
1330 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m | |
NL PV 1000 930 A2 CV L2 | Level 2 |
Asymmetric 02
|
3000 K
|
1400 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 940 A2 CV L2 | Level 2 |
Asymmetric 02
|
4000 K
|
1510 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 20 W / m |
NL PV 1000 922 A2 CV L3 | Level 3 |
Asymmetric 02
|
2200 K
|
1020 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 927 A2 CV L3 | Level 3 |
Asymmetric 02
|
2700 K
|
1620 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 930 A2 CV L3 | Level 3 |
Asymmetric 02
|
3000 K
|
1700 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
NL PV 1000 940 A2 CV L3 | Level 3 |
Asymmetric 02
|
4000 K
|
1840 lm / m | 336 ... 1975 mm | 41 mm | 48 mm | D-Wire | 25 W / m |
Lengths modular in a grid of approx. 162mm possible:
336mm , 672mm , 1000mm , 1225mm , 1650mm , 1975mm
The light inserts are always supplied with an output cable. There is no terminating plug or short-circuit plug required as with the CC system.
In the case of asymmetrical beam angles, when selecting the extension cables, it must be taken into account that the position of the input cable changes depending on the alignment within the profile.